- Home
- ยป
- Our Product Range
- »
- Current Sensors
Current Sensors
IVY-CT-PCB-01-10A High Accuracy Current Transformer
Minimum Order Quantity: 1000 Piece
Product Brochure
| Part Number | IVY-CT-PCB-01-10A |
| Applications | Current transformer can play the role of current conversion & electrical isolation.Universal in used |
| Max Current | 60A |
| Current Ratio | 1(10)A/0.5mA |
| Rated Frequency | 50~60Hz |
1. Current Transformer is also called instrument transformer, including current transformer and voltage transformer.
2. It is used to proportionally convert high voltage or large current into standard voltage (100V) or standard small current (5A or 1A, rated value), to realize the miniaturization and standardization of the measuring instrument, equipment protection and automatic control equipment.
3. Current transformer can also be used to separate the high voltage system to ensure the safety of the personal and equipment.
4. This is IVY compact current trasformer with small size and PCB design, low cost, high accuracy, easy to fix and install. This comprehensive range of 2000:1 ratio CT's is available in current ratings from 1A to 60 A in fully encapsulated PCB mount packages. Applications include smart meter, EV charging, ground fault detection, power transducer, other power and energy monitoring devices.
Product Feature
1. Low profile, compact size, Epoxy resin encapsulated, fully enclosed.
2. PCB mounting type, easy to fix and install.
3. wide linearity range for output current and low phase shift error.
4. Customer specifications are available.
5. Used in universal and be in good interchangeability.
MD0630T41A-1 Earth Leakage Detection Residual Current Sensor
| Type | Closed Loop Current Sensor |
| Brand | IVY Metering |
| Model Number | MD0630T41A-1 |
| Sensed Current Type | AC |
| Installation | Cable Type |
| Plastic Casing | SIP encapsulation |
| Application | Renewables , Industrial Plants, Commercial Buildings ,Medical Facilities |
| Wide voltage input | 12V+-20% |
Product Details
Any electrical leak can be dangerous for your staff and production site. By using IVY Residual Current Device (RCD) you can protect both staff and equipment. Thanks to its zero-flux technology expertise, IVY developed a range of highly flexible Residual Current Monitor of Type B/B+ for measuring DC and AC residual currents up to 100kHz, with digital signal output(AC 30mA/DC 6mA).
MD0630T41A-1 sensor is a new, compact, horizontal type rcd current sensor with pins designed for use in e-mobility infrastructure and AC charging station designs to monitor leakage currents in mode two/three/four electric vehicle charging. MD0630T41A-1 RCD is dedicated to detect to Type A, B and B+ leakage current measurement. The sensor can issues an alarm signal when the DC component of the residual current reaches a preset value.
Product Features
1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955
2. Small Size, Integration Design, Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional
3. Integrated self-monitoring and test functions, Digital Output, Residual Fault Leakage Current Protection
4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs
5. URAT Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
6. Professional Certification: TUV(IEC 62955/IEC 62752/IEC 61851-1); UL 2231-1/UL 2231-2; IS17017; CE-EMC
7. Suitable for EV charger (Load current up to 200A (1-phase) or 150A (3-phase))
MD0630T01A-Z Differential Current Transformer
| Part Number | MD0630T01A-Z |
| Applications | Renewables , Industrial Plants, Commercial Buildings ,Medical Facilities |
| Wide voltage input | 12V+-20% |
| Measuring current range | DC current 2-15mA; AC current 3-100mA |
| Three outputs | DC alarm, AC alarm, AC/DC alarm |
Product Introduction :
MD0630T01A-Z RCD is dedicated to detect to Type AC A, B and B+ leakage current measurement. The sensor can issues an alarm signal when the DC component of the residual current reaches a preset value.
Product Features :
1. Small Size; Compact/Integration Design; Horizontal Type, with Pins.
2. Integrated self-monitoring and test functions; B Type Leakage Protection
3. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output
4. UART Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019
5. Certification: TUV(IEC62955/IEC62752/IEC61851-1/IEC62196); UL2231-1/UL2231-2; IS17017; CE-EMC
6. Built-in RCD Sensor, Electrical Safety at Low Cost (Compared to Type B RCCB)
7. Robust Mechanical and Electrical Design for Harsh Environmental Conditions
MD0630T01A-2 AC DC Earth Leakage Detector Sensor
Minimum Order Quantity: 1000 Piece
| Part Number | MD0630T01A-2 |
| Wide voltage input | 12V+-20% |
| Measuring current range: | DC current 2-15mA; AC current 3-100mA |
| Three outputs | DC alarm, AC alarm, AC/DC alarm |
MD0630T01A-2 is an automotive grade smallest leakage current sensor designed for portable charger also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, leakage current detector and fault current sensor. Type A, B and B+, dedicated to detect to DC, AC and DC+AC leakage current measurement. The internal parts of the portable charger should be as small as possible, our new leakage detector is small and lightweight, which just meets this requirement. This residual current monitor will detect DC and AC residual currents in 50Hz/60Hz AC installations according to IEC62955. It's primarily intended for use in Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition. It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs.
Product Advantages :-
- Ultra-small, Flexible, Integration Design, Residual current range 2~100 mA
- Switching output for 6 mA DC/30 mA (IEC) or 5 mA /20 mA (UL 2231)
- Error(Fault) output (Integrated self-monitoring and test functions)
- Digital Output, Measurement resolution DC 0.2 mA AC 0.3mA
- Full load current up to 200A (1-phase) or 150A (3-phase)
- AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs
- Robust mechanical design suitable for harsh electronic environments
- Total system cost significantly reduced compared to type B RCCB
- URAT Comm. with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019