Providing you the best range of md0630t01a leakage current detection type b rcd sensor, md0630sta-p ac dc leakage sensor, md36da-c dc leakage current sensor, md0630t41a earth leakage detection residual current sensor, md0630sta-c zero phase current transformer and ac12-450t15da 3-phase single output pcb mount ac dc converter power supply module with effective & timely delivery.

MD0630T01A Leakage Current Detection Type B RCD Sensor

MD0630T01A Leakage Current Detection Type B RCD Sensor
  • MD0630T01A Leakage Current Detection Type B RCD Sensor
  • MD0630T01A Leakage Current Detection Type B RCD Sensor
  • MD0630T01A Leakage Current Detection Type B RCD Sensor
Get Best Quote
Product Price: Rs 2,500 / PieceGet Best Price

Minimum Order Quantity: 33 Piece

Product Brochure

Product Details:
Current Measuring Range20 A
BrandIVY Metering
Model NumberMD0630T01A
Residual Current6mA DC 30mA AC
Three outputsDC alarm, AC alarm, AC/DC alarm
Measuring current range:DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

Product Introduction :-

IVY offers MD0630T01A for monitoring or providing shock protection&fault protection on AC and DC installations and for EV charging applications. MD0630T01A is a RCD sensor specifically developed for EV-charging providing all-current sensitivity. The sensor can issues an alarm signal in case of hazardous electrical faults (DC and AC). It has the characteristics of accurate measurement, small size and integration. The RCD sensor can be set separately for AC and DC leakage and has a digital output function. 

 

MD0630T01A is an automotive grade leakage current sensor family also called Residual Current Monitoring (RCM) or Residual Current Detection (RCD) class B and B+, dedicated to DC, AC, and AC+DC leakage current measurement. The MD series is the IVY Metering RCM type B current sensor family designed to measure and protect from AC and DC fault currents (leakage current). Our sensor to have best in class accuracy hence protecting it from potential fire hazards and electrical shocks. The MD series sensors provide a fault current output and enable fast response time and detailed fault information. 

 

Product Features :-

1. Small Size, Integration Design, Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional

2. Integrated self-monitoring and test functions; Type B Leakage Protection

3. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output

4. UART Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019

5. Professional Certification: TUV(IEC62955/IEC62752/IEC61851-1); UL 2231-1/UL 2231-2; IS17017, CE-EMC 

6. Electrical Safety at Low Cost (Compared to Type B RCCB)

7. Robust Mechanical and Electrical Design for Harsh Environmental Conditions

Yes! I am InterestedRequest A Callback

MD0630STA-P AC DC Leakage Sensor

MD0630STA-P AC DC Leakage Sensor
  • MD0630STA-P AC DC Leakage Sensor
  • MD0630STA-P AC DC Leakage Sensor
  • MD0630STA-P AC DC Leakage Sensor
Get Best Quote
Product Price: Rs 1,500 / PieceGet Best Price

Minimum Order Quantity: 140 Piece

Product Brochure

Product Details:
Current Measuring Range20 A
Typeearth leakage sensor
BrandIVY-Metering
Model NumberMD0630STA-P
HIgh Frequency1kHz
InstallationPCB Type
MD0630STA-P AC DC Leakage Sensor :

MD0630STA-P earth leakage sensor detect both AC and DC ground faults in a very small, PCB-style form factor. The RCD module is designed for integration directly into inverters. Outputs way is open collector output. With the characteristics of high sensitivity, accurate measurement, small size, and integration. When a DC leakage current of 3~6mA or an AC leakage current of 15~30mA is detected, an alarm signal will be output.  

 

The ground fault detection module is intended for the detection of DC and/or AC residual currents in 50Hz/60Hz AC or DC installations. Residual current detection options for IEC based requirements are 30mA AC & 6mA DC or 20mA AC & 6mA DC for UL requirements. It can not only detect AC fault current, DC pulsing and smooth DC fault current, but also sinus wave AC fault current at a high frequency up to 1kHz. IVY MD series leakage current sensors are optimized for fast, low-cost assembly, combined with the highest product and production quality. In addition to the use of PV inverter. Also suitable for EV charger, medical instruments, UPS, smart home, industrial machines, fire distribution cabinet, IOT etc. Protecting personal and electrical equipment safety.

Yes! I am InterestedRequest A Callback

MD36DA-C DC Leakage Current Sensor

MD36DA-C DC Leakage Current Sensor
  • MD36DA-C DC Leakage Current Sensor
  • MD36DA-C DC Leakage Current Sensor
  • MD36DA-C DC Leakage Current Sensor
Get Best Quote
Product Price: Rs 1,800 / PieceGet Best Price

Product Details:
Current RangeDC Current 2~15mA
Part NumberMD36DA-C
BrandIVY-Metering
InstallationCable/Horizontal Installation
ApplicationResidual Current Protection
CertificationRoHS
MD36DA-C DC Leakage Current Sensor :
  • MD36DA-C is a high sensitivity and cost-effective dc leakage current sensor also colled residual direct current monitoring module, residual direct current monitoring device(RDC-MD), residual direct current detecting device(RDC-DD), residual direct current protective device(RDC-PD) intended for the detection of DC residual currents at 6mA or greater in 50Hz/60Hz AC installations.
  • This DC RCD module detect smooth DC and half-wave DC currents. Which, electrically coupled to a protection unit, in full compliance with the requirements of IEC 62955. As an option, the module can also integrate residual alternate current monitoring.
  • The rcd module is suitable for use in AC charging stations permanently connected to the mains (mode 3 according to IEC 61851-1)
Product Advantages :
  • DC 2~15mA micro current detection
  • DC 3~6mA Alarm (Needn’t Set)
  • Self-test Function, Open Collector Alarm Output
  • Integrated Design, Cable/Horizontal Type Installation
  • Various types of dc leakage current monitoring(typeAC/A/F/B)
  • Cost-effective Product
Product Application :
  1. Being able to detect smooth DC residual currents which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and of the installation
  2. can guarantee dependable protection for field technicians and installed machinery by detecting high frequency residual current and protecting against smooth DC residual currents in the event of a fault.
  3. can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of order can cause discomfort.
  4. In installation where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures and interruption of any critical operation


Model NO.MD36DA-CProduction ProcessIntegrationMaterialPlasticApplicationResidual Current ProtectionCertificationRoHSCustomizedCustomizedProduct NameDC Leakage SensorCurrentDC Current 2~15mAInstallationCable/Horizontal InstallationAlarm OutputOpen CollectorApplication ScenariosEV Charger, Industrial Device, New Energy FieldTheoryCurrent SensorPlastic CasingSIP EncapsulationTransport PackageCartonsSpecificationTBATrademarkIVY
Yes! I am InterestedRequest A Callback

MD0630T41A Earth Leakage Detection Residual Current Sensor

MD0630T41A Earth Leakage Detection Residual Current Sensor
  • MD0630T41A Earth Leakage Detection Residual Current Sensor
  • MD0630T41A Earth Leakage Detection Residual Current Sensor
  • MD0630T41A Earth Leakage Detection Residual Current Sensor
Get Best Quote
Product Price: Rs 2,500 / PieceGet Best Price

Product Details:
Sensor Typeresidual current sensor
Accuracyat 25℃, DC±0,2mA, AC±0.3mA
Part NumberMD0630T41A
BrandIvy Metering
Wide voltage input12V±20%
Measuring current rangeDC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
MD0630T41A Earth Leakage Detection Residual Current Sensor :

MD0630T41A Earth Leakage Detection Residual Current Sensor :Product Details 
  • MD0630T41A is a cable & pcb mount AC DC leakage current sensor, which can also be called residual current sensor, residual current monitor (RCM), residual current device (RCD) and differential current sensor.
  • It can detect DC and AC residual currents in 50Hz/60Hz AC installations according to IEC62955. It's primarily intended for use in Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition.
  • It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs.
Product Advantages :
  1. Small Size, Compact Design, Residual current range 2~15mA DC/3~100mA AC
  2. Digital output for 6 mA DC/30 mA (IEC) or 5 mA /20 mA (UL 2231)
  3. Full load current up to 200A (1-phase) or 150A (3-phase)
  4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs
  5. Robust mechanical design suitable for harsh electronic environments
  6. Total system cost significantly reduced compared to type B RCCB
Product Parameters :
  • Wide voltage input: 12V±20%
  • Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
  • Accuracy: at 25℃, DC±0,2mA, AC±0.3mA
  • Can read current value and set alarm current value
  • Three outputs: DC alarm, AC alarm, AC/DC alarm
  • Working environment temperature: -25℃~+80℃
  • Plastic case, small SIP package
Product Applications :
  • By using a IVY MD series RCD sensor integrated into an IC-CPD or wall box, customers can save the high costs of installing a type B RCCB to provide all-current sensitivity and electrical safety at low cost.
  • As the residual currents to be monitored only occur in the event of electrical faults and are extremely low (mA), maximum measurement precision is critical.
  • In addition, a fast response time is required to maintain safety features.
Yes! I am InterestedRequest A Callback

MD0630STA-C Zero Phase Current Transformer

MD0630STA-C Zero Phase Current Transformer
  • MD0630STA-C Zero Phase Current Transformer
  • MD0630STA-C Zero Phase Current Transformer
  • MD0630STA-C Zero Phase Current Transformer
Get Best Quote
Product Price: Rs 1,950 / PieceGet Best Price

Minimum Order Quantity: 76 Piece

Product Details:
Electronic Transformer TypePush Pull Transformers
Country of OriginMade in India
Model No.MD0630STA-C
BrandIVY Metering
Applicationuse of charging piles. Also suitable for inverters, UPS, smart home, industrial machines, IOT

Product Details : 

 

Charging of electric vehicles at a standard wall socket or a wall box requires protection devices against DC fault currents to avoid electric shock. Installed type A residual current circuit breakers (RCCBs) are unable to identify and deactivate DC fault currents. IVY differential current transformer offer the opportunity to save the cost and space for a costly type B RCCB in IC-CPD or wall boxes. MD0630STA-C is a leakage current sensor with the characteristics of high sensitivity, accurate measurement, small size, and integration. When a DC leakage current of 3~6mA or an AC leakage current of 15~30mA is detected, an alarm signal will be output. At the same time, it has a self-test function, which can be used to judge in real time whether the sensor is in a normal working state. If the sensor fails, the self-test output terminal will not be able to output a feedback signal.

Product Advantages :

  • DC 2~15mA/AC 3~100mA micro current detection
  • DC 3~6mA/AC 15~30mA Alarm (Needn’t Set)
  • Fault current detection according to IEC 62752 or UL 2231
  • Load current up to 80 Arms (1-phase) or 3 x 32 Arms (3-phase)
  • Open collector output for 6 mA DC and 30 mA AC (acc. to IEC 62955)
  • Integrated self-monitoring and test functions
  • Small volume, saves costly type B RCD
  • AC/DC-current sensitivity at low cost

Product Applications :

  1. Being able to detect smooth DC residual currents which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and of the installation
  2. can guarantee dependable protection for field technicians and installed machinery by detecting high frequency residual current and protecting against smooth DC residual currents in the event of a fault.
  3. can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of order can cause discomfort.
  4. In installation where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures and interruption of any critical operation

 

 

 

 

Yes! I am InterestedRequest A Callback

AC12-450T15DA 3-Phase Single Output PCB Mount AC DC Converter Power Supply Module

AC12-450T15DA  3-Phase Single Output PCB Mount AC DC Converter Power Supply Module
  • AC12-450T15DA  3-Phase Single Output PCB Mount AC DC Converter Power Supply Module
  • AC12-450T15DA  3-Phase Single Output PCB Mount AC DC Converter Power Supply Module
  • AC12-450T15DA  3-Phase Single Output PCB Mount AC DC Converter Power Supply Module
Get Best Quote
Product Price: Rs 975 / PieceGet Best Price

Product Brochure

Product Details:
Output Voltage5V-15V
BrandIvy Metering
Input Voltage110-450V
Part NumberAC12-450T15DA
Input Frequency Range120mVp-p
AC12-450T15DA  3-Phase Single Output PCB Mount AC DC Converter Power Supply Module :

Product Introduction :
  • AX series is a small size, high efficiency PCB mount ac-dc power supply module.
  • This series of power supplies have the advantages of three-phase input voltage, AC and DC dual usage, low ripple, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. 
  • Application for many fields such as smart home, industrial equipment, medical instruments, EV charging station, smart neter, and lighting control.
Product Features:
  • 110-450V(input voltage) to 5V-15V(output voltage)
  • PCB board in-line Type Installation
  • Withstand Voltage Up to 4000Vac
  • Built-in anti-4KV lightning surge and anti-EMI circuit at the power input
  • Over current / Short circuit /Over temperature protection
  • Single/Dual Output Optional, Three Phase Input
Yes! I am InterestedRequest A Callback

MD0630STA-PM Type B GFCI Sensor Earth Leakage Detection ZCT Differential Transformer

MD0630STA-PM Type B GFCI Sensor Earth Leakage Detection ZCT Differential Transformer
  • MD0630STA-PM Type B GFCI Sensor Earth Leakage Detection ZCT Differential Transformer
  • MD0630STA-PM Type B GFCI Sensor Earth Leakage Detection ZCT Differential Transformer
Get Best Quote
Product Price: Rs 1,400 / PieceGet Best Price

Product Brochure

Product Details:
Protection FunctionEarth Leakage
Part NumberMD0630STA-PM
BrandIVY Metering
Wide voltage inputDC 4.85-5.5V
Alarm outputOpen collector output
Measurement current rangeDC 2-15mA, AC 3-100mA
MD0630STA-PM Type B GFCI Sensor Earth Leakage Detection ZCT Differential Transformer for Solar Inverter :MD0630STA-PM Introduction :
  • The MD0630STA-PM AC DC leakage current sensor(compatible with Type A and Type B) features high sensitivity, accurate measurement, and a compact & integrated design.
  • It outputs an alarm signal when it detects a DC leakage current of 3-6mA or an AC leakage current of 15-30mA. It also has a self-test function.
  • Its outstanding features are its ultra-small size and ultra-low price(Type B Quality, Type A Price).
Product Feature :
  • Wide voltage input: DC 4.85-5.5V
  • Measurement current range: DC 2-15mA, AC 3-100mA
  • Alarm current range: DC 3-6mA, AC 15-30mA
  • Alarm output: Open collector output
  • Short response time
  • Compact design
  • Self-test function: Use the test pin to determine whether the sensor is functioning properly
  • Operating temperature: -25°C to +80°C
Yes! I am InterestedRequest A Callback

IM-SP401A 40A Single Pole Non Latching Disconnect Relay for Level 2 Charger

IM-SP401A 40A Single Pole Non Latching Disconnect Relay for Level 2 Charger
  • IM-SP401A 40A Single Pole Non Latching Disconnect Relay for Level 2 Charger
  • IM-SP401A 40A Single Pole Non Latching Disconnect Relay for Level 2 Charger
  • IM-SP401A 40A Single Pole Non Latching Disconnect Relay for Level 2 Charger
Get Best Quote
Product Price: Rs 100 / PieceGet Best Price

Product Brochure

Product Details:
Model Name/NumberIM-SP401A
Max Switching Current40A
Max Switching Voltage277VAC
Max Switching Power11080VA
humidity5%~85%RH
IM-SP401A 40A :

  • IM-SP401A is a single pole normally open small high capacity 32A 40A PCB Circuit Board Relay, It has the characteristics of low temperature rise, low power consumption, miniature size and cost-effective desigh. It can withstand 1000A 1ms/three times short-time over-current. 
  • It is primarily designed for electrical vehicle charging stations, charging cables and for photovoltaic inverter applications. Other applications include stand by power units, UPS, washing machines and dryer disconnections. 
  • There are two standards in the car charging pile industry, the national standard 16A and the national standard 32A. For different currents, the rated current of the selected relay will also be different.
  • The car charging pile has slow charging and fast charging. The cost of slow charging is lower than that of fast charging. Slow charging Relays are used, while high-voltage contactors are used for fast charging, up to 7kv when working, and the power consumption is high at the same time. Now the main advantage is the slow charging. The slow charging 16A standard generally uses a 40A relay.
Yes! I am InterestedRequest A Callback

IM-NE801A-12-2A-P Non Latching Relay for AC Charging Station

IM-NE801A-12-2A-P Non Latching Relay for AC Charging Station
  • IM-NE801A-12-2A-P Non Latching Relay for AC Charging Station
  • IM-NE801A-12-2A-P Non Latching Relay for AC Charging Station
  • IM-NE801A-12-2A-P Non Latching Relay for AC Charging Station
Get Best Quote
Product Price: Rs 600 / PieceGet Best Price

Product Brochure

Product Details:
Model Name/NumberIM-NE801A-12-2A-P
Weight ( g )70g
Dimension(mm)49x30x26.5
Continuous Current40A
Power Consumption1.8W/3.0W
Product Description :

Product Details

  • AC switching elements are a crucial part of safety and protection function in charging stations and cables. Key parts of the IVY line-up are the 40A IM-NE801A 2 pole power relay and 60A IM601 1 pole bistable relay. Which fulfill either IEC 61851-1 or the recent IEC 62955 norm. IM-NE801A main features as follow: 
  • Switching Capacity: 40A 277VAC; Contact Form: 2A; Low Temperature Rise; Sealed Structure to Resist Harsh Environment; UL/TUV Certified, IEC61810-1 Compliant. 
  • The relay has short-time overcurrent characteristics, can withstand three times of 1000A 1ms overcurrent, and the contacts will not be damaged, and can continue to work normally to open and close.
  • More importantly, the main advantages of lie in large conntact gap:
  • Its contact distance can be up to 3mm, and the contact spacing of the general relay is about 0.8mm or 1.5mm. In some ways this feature made contact between medium pressure can improve a lot, the higher the withstand voltage value, and also solve the problem of contact resistance increase rapidly, etc, under non-operation status it can avoid wrong operation or damage caused by external factors. which improves the tensile arc resistance of the contact and prolongs the service life of the relay.

 


Yes! I am InterestedRequest A Callback

MD20STA-C Leakage Detection GFCI Sensor

MD20STA-C Leakage Detection GFCI Sensor
  • MD20STA-C Leakage Detection GFCI Sensor
  • MD20STA-C Leakage Detection GFCI Sensor
  • MD20STA-C Leakage Detection GFCI Sensor
Get Best Quote
Product Price: Rs 1,800 / PieceGet Best Price

Product Details:
Part NumberMD20STA-C
BrandIVY-Metering
Leakage alarmDC 40×1.414mA /AC 15~20mA
Leakage ProtecionAC,DC,AC+DC CCID20
Power Supply12V ±20%.
Operating Temperature Range-25°C to +80°C.
InstallationCable Type/Horizontal
FunctionSelf-testing
AppearancePlastic casing V0
Leakage Detection GFCI Sensor MD20STA-C :
  • This is a zero phase leakage current transfomer that complies with the UL2231-2 standard, and its leakage protection type is CCID20.
  • The AC leakage protection threshold is 15~20mA, and the DC leakage protection threshold is 40×1.414=56.56mA.
  • It also protects against mixed leakage current and high-frequency leakage. When the leakage current in the line reaches the above alarm threshold, it will output a leakage alarm signal (OC gate output).
  • In addition, it has a self-test function, which can be used to determine in real time whether the sensor is in a normal working state. If the sensor fails, the self-test output terminal will not be able to output the self-test feedback signal (Open Collector Output), so this leakage sensor will be safer and more reliable in the field of leakage protection.
Product Advantages :
  • DC 40×1.414mA /AC 15~20mA Leakage Alarm 
  • With Self-test Function, Open Collector Output
  • Integrated Design, Cable/Horizontal Type Installation
  • Robust mechanical and electrical design suitable for harsh environmental conditions
  • Electrical safety at low cost (compared to RCCB)
  • Compliant with standard UL 2231-1/2
Yes! I am InterestedRequest A Callback

IM901 19120-S Bistable SPST PCB Latching Relay

IM901 19120-S Bistable SPST PCB Latching Relay
  • IM901 19120-S Bistable SPST PCB Latching Relay
  • IM901 19120-S Bistable SPST PCB Latching Relay
  • IM901 19120-S Bistable SPST PCB Latching Relay
Get Best Quote
Product Price: Rs 450 / PieceGet Best Price

Product Brochure

Product Details:
Part Number19120-S
IM901 19120-S Bistable SPST PCB Latching Relay :

IM901 Product Features 

Meet to IEC62055-31—UC2 UC3

Meet the requirements of anti-frequency magnetic field and magnetic interference in the national network.

According to RoHS requirements

Large switching power with mini body

Big strength of magnetic latching power, anti-shock of vibration

Pulse drive, low power consumption, and high stability

Small contact resistance, and little self-consumption with reliable working

Custom assemblies available with flex wire and/or copper straps, and/or with integrated shunt

 

Application Scenarios

1) Smart meters: IC card meters, prepaid meters, single-phase meters, three-phase meters.
2) Reactive power compensation: synchronous switch, composite switch, smart capacitor.
3) Intelligent control: smart home, solar street light control, automation equipment, etc.

4) New Energy Field: EV charger, PV Inverter

 

Product Parameters

  • Contact Form: 1A/B

  • Contact Material: AgSnO2

  • Max. Switching Voltage: 250VAC

  • Max. Switching Current: 90A

  • Max. Switching Power: 22500VA

  • Contact Resistance: ≤1mΩ

  • Pick-up Time: 20ms

  • Release Time: 20ms

  • Electrical Endurance: 10000 Cycles

  • Mechanical Endurance: 100000 Cycles

  • Temp.Rise: ≤55K When Ambient 40℃ 

Yes! I am InterestedRequest A Callback

IM601 16120-S Bistable SPST PCB Latching Relay

IM601 16120-S Bistable SPST PCB Latching Relay
Get Best Quote
Product Price: Rs 450 / PieceGet Best Price

Product Brochure

Product Details:
Part Number16120-S
IM601 16120-S Bistable SPST PCB Latching Relay :

60A Bistable RELAY

  • Max. Switching Current:60A
  • Rated Coil Consumption:1.5/3W(20ms)
  • Dimension:38*30*16.5mm
  • IEC62055-31 UC2 Certified,IEC61810-1 Compliant
  • Widely used in EV field, industrial control field, etc.
Product Introduction :
  • IM601 is a small industrial bistable latching power relay with continuous current up to 60A, and switching 60A 250VAC. Single and Double coil latching. Used in utility meters and for solar, EV charger and energy conservation.
  • AC switching elements are a crucial part of safety and protection function in charging stations and cables. Key parts of the IVY line-up are the 40A IM-NE801A 2 pole power relay and 60A IM601 bistable relay. Both types are available with a mirror contact according to IEC 60947-1 and VDE / TUV/UL approvals.
  • They can be used in the latest generation of wall boxes which fulfill either IEC 61851-1 or the recent IEC 62955 norm.
IM601 60A Power Latching Relay  :
  • Switching Capacity: 60A, 250VAC
  • Single/Dual Coil Optional
  • 4kV dielectric strength between coil and contacts
  • Custom assemblies available with flex wire and/or copper straps, and/or with integrated shunt
  • IEC62055-31 UC2 UC3 Certified
Yes! I am InterestedRequest A Callback